Workshop
Ask a question
since January
March
Frank2024
Getting Established
  • My latest posts
  • Posts I liked
  • My liked posts

User's latest posts

Frank2024
Getting Established
1 reply
January

Yes that’s my concern. F shaped end side capa available onlr to Sunlite 10mm. Water even can flow to top necause od wind. A lot of wster will flow ove ...

Frank2024
Getting Established
1 reply
January

Thank you for your advice but tt was not about the bottom end cap nor the top end. Even 20mm back flow stop cap would be for corrugated poly carbonat ...

Frank2024
Getting Established
1 reply
January

Thx Eric. I would have to install it per the supplier ‘s installation guide - bottom end cap is a must, top end depends on

Frank2024
Getting Established
5 replies

I could not find any F-shaped side end cap for this Sunlite 8mm sheet. So I might have to fix the side end directly to batten timber with screw. Then ...

Frank2024
Getting Established
4 replies

I am using two pieces of 90x45 timber to make bearer. There is gap between two timbers binded by screws. Can normal external gap filler prevent wood ...

Frank2024
Getting Established
4 replies

Hi I am planning rrafter and other roof structure for new deck. I am considering 8mm polycarbobate flat sheet. I could not understand from the suppli ...

Frank2024
Getting Established
3 replies

Hi I am building a covered deck. I bought these 88 mm timber posts, and 90 mmm stirrup steel anchors. Is it ok to set up 88 mm posts on 90 mm anchor ...

Posts user liked

Bunnings Team Member MitchellMc
Bunnings Team Member
January

Hi @Frank2024 You might like to install the sheeting to the batten with the wide-headed screws and then install an aluminium profile along the side ...

Jewelleryrescue
Kind of a Big Deal
January

Hi @Frank2024 The structual wieght of your timber posts is going downwards and all its load. You can always tap the stirrups with a hammer and clos ...

Bunnings Team Member EricL
Bunnings Team Member
1 reply
January

Hello @Frank2024 I suggest covering the surface of the bearer with CAgroup 50mm x 20m Bearer Protector G-Tape. Put one in the centre to cover the g ...

Bunnings Team Member EricL
Bunnings Team Member
2 replies
January

Hello @Frank2024 Thats excellent advice coming from @Jewelleryrescue. Another reason you need to use the ends caps is to prevent moisture ingress i ...

Jewelleryrescue
Kind of a Big Deal
2 replies
January

Hi @Frank2024 It sounds like you need a below item but hard to picture you situation 100% with out picture but see if we are close.Suntuf ...

Jewelleryrescue
Kind of a Big Deal
January

Hi @Frank2024 Your right that extra hard ware cant trap dirt etc but to my experiance the end caps are there to encapslate and hold the polycarbo ...

Bunnings Team Member MitchellMc
Bunnings Team Member
January

Welcome to the Bunnings Workshop community @Frank2024. It's brilliant to have you join us, and many thanks for your question about post supports.I thi ...

Retired Team Member Akanksha
Retired Team Member
January

Let me also extend a warm welcome to the Bunnings Workshop community, @Frank2024. We're delighted to have you join us. Great to see you've received ad ...

User's liked posts

Frank2024
Getting Established
1 reply
January

Thx Eric. I would have to install it per the supplier ‘s installation guide - bottom end cap is a must, top end depends on

Frank2024
Getting Established
4 replies

Hi I am planning rrafter and other roof structure for new deck. I am considering 8mm polycarbobate flat sheet. I could not understand from the suppli ...

Frank2024's Bookmarks
No posts to display.
Contact Me
Online Status
Offline
Date Last Visited
March